Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →When a fire strategy, inspection report or building control comment in High Wycombe calls for glazing tested to resist fire, our fire-rated escape route glazing service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.
Our Buckinghamshire coverage takes in High Wycombe (HP13, HP11, HP12, HP15) and the neighbouring towns of Amersham, Maidenhead, Chesham. High Wycombe lies roughly 46 km from Milton Keynes, within our Buckinghamshire coverage.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in High Wycombe identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Fire-rated escape route glazing applies to many building types in High Wycombe, including healthcare buildings and care homes.
Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Building work in High Wycombe follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Survey timing in High Wycombe depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in High Wycombe and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.