Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →From the SL6 district outwards, we arrange fire-rated escape route glazing for buildings across Maidenhead, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
Glazing into a protected stair needs particular care; the rules depend on whether the stair is part of a protected shaft and how the building is used.
Whether the building is in central Maidenhead or the wider SL6, SL60 districts, we can survey and quote. We also cover Slough, Windsor, High Wycombe. Maidenhead lies roughly 19 km from Reading, within our Berkshire coverage.
We can phase work in Maidenhead around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Maidenhead building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Maidenhead identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for retail and leisure units, schools and colleges and other building types in Maidenhead.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Maidenhead follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Maidenhead confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.