Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Our integrity fire glass service covers Chatham and neighbouring areas such as Gillingham and Rochester, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Integrity fire glass, classified E, stops flames and hot gases passing for the rated time but does not limit the heat coming through. EW glass adds a cap on the heat radiated through the glass. Both are thinner, lighter and cheaper than fully insulated glass.
Coverage around Chatham includes the ME4, ME7, ME5, ME1, ME2 districts and nearby Gillingham, Rochester, Strood. Maidstone, around 13 km from Chatham, is the largest town in the same coverage area.
E glass gets hot in a fire. Furniture or stored materials beside it can ignite from radiated heat.
EW glass limits radiation to 15 kW/m² measured one metre from the glass, reducing the risk of igniting materials or harming people nearby.
Integrity-only glass may be acceptable in some fire-resisting partitions, screens and doors, often at high level, within the limits national guidance sets. Compartment walls normally need insulating (EI) glazing.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
After survey you get a fixed written quote for the agreed scope, so Chatham budgets are not open-ended.
Every quote in Chatham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can survey and quote for care homes, schools and colleges and other building types in Chatham.
Yes, considerably, and it is thinner and lighter.
EW glass also limits heat radiation through the glass, which reduces the risk to people and materials near it.
Building work in Chatham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Chatham to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.