Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Insulated fire glass in Chichester is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
EI glass is the choice where people need to pass close to the glass during a fire, where combustible materials sit near it, or where building guidance would otherwise restrict glazing. We supply and fit EI 30 to EI 120 glass in tested frames, internally and externally.
Every quote in Chichester identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Chichester budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Some EI products are internal only. External use needs a product and edge seal approved for UV and weather.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
We cover Chichester and the surrounding postcode districts, including PO19, PO20. Nearby towns we also serve include Bognor Regis, Havant, Littlehampton. Chichester lies roughly 52 km from Crawley, within our West Sussex coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Insulated fire glass applies to many building types in Chichester, including care homes and public buildings.
Only products approved for external use, usually in a sealed unit with UV protection.
Yes. Once the interlayers have reacted, the glass has done its job and must be replaced.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Chichester to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.