Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →When a fire strategy, inspection report or building control comment in Chester-le-Street calls for glazing tested to resist fire, our insulated fire glass service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
Whether the building is in central Chester-le-Street or the wider DH3, DH2 districts, we can survey and quote. We also cover Washington, Houghton-le-Spring, Stanley. Chester-le-Street is about 37 km from Darlington, the largest town in our County Durham coverage.
After survey you get a fixed written quote for the agreed scope, so Chester-le-Street budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can phase work in Chester-le-Street around residents, staff or pupils, with out-of-hours options.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover retail and leisure units, public buildings and other buildings in Chester-le-Street.
Yes. Once the interlayers have reacted, the glass has done its job and must be replaced.
Only products approved for external use, usually in a sealed unit with UV protection.
Building work in Chester-le-Street follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Chester-le-Street to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.