Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Looking for insulated fire glass in Irvine? We survey, supply and install tested fire-rated glazing for schools and colleges, industrial units and other buildings in and around Irvine, including the KA12 postcode district.
Tell us what you need. We reply with next steps and a guide price.
EI glass is the choice where people need to pass close to the glass during a fire, where combustible materials sit near it, or where building guidance would otherwise restrict glazing. We supply and fit EI 30 to EI 120 glass in tested frames, internally and externally.
Survey visits can be arranged anywhere in Irvine, including the KA12, KA11, KA13 districts, and in nearby Kilmarnock, Ayr, Newton Mearns. Irvine lies roughly 10 km from Kilmarnock, within our Ayrshire coverage.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
Some EI products are internal only. External use needs a product and edge seal approved for UV and weather.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.
We can phase work in Irvine around residents, staff or pupils, with out-of-hours options.
Every quote in Irvine identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can survey and quote for schools and colleges, industrial units and other building types in Irvine.
Only products approved for external use, usually in a sealed unit with UV protection.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Irvine is in Scotland, so work needs a building warrant and follows the Building Standards Technical Handbooks, with the Fire (Scotland) Act 2005 covering occupied premises.
Survey timing in Irvine depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Irvine to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.