Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →For Saddleworth buildings, we supply, replace and check fire-rated windows wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Most fire-rated windows are fixed lights, because opening windows need the opening sash, hinges and locks to be tested too. We supply and install fixed and, where tested, opening fire-rated windows in steel, aluminium and timber, matched to the surrounding windows where possible.
If an existing frame in a Saddleworth building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Saddleworth identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If a fire-rated window cannot open, ventilation may need another route. We coordinate with the designer.
Replacing a non-rated window near a boundary is often triggered by an extension or change of use. We survey the opening before quoting.
The closer a wall is to a boundary, the less unprotected area it can have. Fixed windows that meet the wall's full fire-resistance requirement, including insulation where required, are not counted as unprotected area; integrity-only glazing generally still is.
Coverage around Saddleworth includes the OL3, OL4, OL5 districts and nearby Oldham, Royton, Stalybridge. Saddleworth lies roughly 17 km from Manchester, within our Greater Manchester coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for schools and colleges, hotels and other building types in Saddleworth.
Some can, if the opening version has been tested. Fixed fire-rated windows are more common.
No. The frame, glazing system and fixings also need to be part of a tested window.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Saddleworth follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Saddleworth to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.