Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Fire-rated windows in Ashton-under-Lyne is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated windows are windows tested as complete units to resist fire, needed where an external wall must protect a neighbouring property, where a window looks onto a protected stair or escape route, or where two parts of a building face each other at close range.
The closer a wall is to a boundary, the less unprotected area it can have. Fixed windows that meet the wall's full fire-resistance requirement, including insulation where required, are not counted as unprotected area; integrity-only glazing generally still is.
If a fire-rated window cannot open, ventilation may need another route. We coordinate with the designer.
An opening sash introduces gaps and hardware that all need testing. Fixed fire-rated windows are simpler and more widely available.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Survey visits can be arranged anywhere in Ashton-under-Lyne, including the OL7, OL6, SK16, SK15, M43, OL8 districts, and in nearby Dukinfield, Stalybridge, Droylsden. Manchester, around 9 km from Ashton-under-Lyne, is the largest town in the same coverage area.
After survey you get a fixed written quote for the agreed scope, so Ashton-under-Lyne budgets are not open-ended.
Every quote in Ashton-under-Lyne identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Ashton-under-Lyne building has no traceable evidence, we say so and price the options rather than guess.
Fire-rated windows applies to many building types in Ashton-under-Lyne, including care homes and hotels.
No. The frame, glazing system and fixings also need to be part of a tested window.
Usually when a wall is close to a boundary, when a window overlooks a protected escape route, or when part of a building faces another part at close range. Your designer or building control will confirm.
Survey timing in Ashton-under-Lyne depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Ashton-under-Lyne and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.