Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Our fire-rated windows service covers Uxbridge and neighbouring areas such as Ruislip and Hayes, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated windows are windows tested as complete units to resist fire, needed where an external wall must protect a neighbouring property, where a window looks onto a protected stair or escape route, or where two parts of a building face each other at close range.
Our Greater London coverage takes in Uxbridge (UB8, UB10, SL0, UB9, UB11, HA4) and the neighbouring towns of Ruislip, Hayes, Gerrards Cross. Uxbridge is one of the Greater London districts we cover.
Rated windows can usually be finished to match the rest of the elevation.
An opening sash introduces gaps and hardware that all need testing. Fixed fire-rated windows are simpler and more widely available.
The closer a wall is to a boundary, the less unprotected area it can have. Fixed windows that meet the wall's full fire-resistance requirement, including insulation where required, are not counted as unprotected area; integrity-only glazing generally still is.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
If an existing frame in a Uxbridge building has no traceable evidence, we say so and price the options rather than guess.
We can phase work in Uxbridge around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Uxbridge budgets are not open-ended.
Sector guides below cover schools and colleges, hotels and other buildings in Uxbridge.
Frames can be slightly heavier, but most can be finished to match surrounding windows.
No. The frame, glazing system and fixings also need to be part of a tested window.
Survey timing in Uxbridge depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Uxbridge confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.