Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →From the EX16 district outwards, we arrange fire-rated windows for buildings across Tiverton, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated windows are windows tested as complete units to resist fire, needed where an external wall must protect a neighbouring property, where a window looks onto a protected stair or escape route, or where two parts of a building face each other at close range.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can phase work in Tiverton around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Tiverton budgets are not open-ended.
Replacing a non-rated window near a boundary is often triggered by an extension or change of use. We survey the opening before quoting.
The closer a wall is to a boundary, the less unprotected area it can have. Fixed windows that meet the wall's full fire-resistance requirement, including insulation where required, are not counted as unprotected area; integrity-only glazing generally still is.
Rated windows can usually be finished to match the rest of the elevation.
Coverage around Tiverton includes the EX16 districts and nearby Exeter, Taunton, Exmouth. Plymouth, around 75 km from Tiverton, is the largest town in the same coverage area.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover public buildings, blocks of flats and other buildings in Tiverton.
No. The frame, glazing system and fixings also need to be part of a tested window.
Usually when a wall is close to a boundary, when a window overlooks a protected escape route, or when part of a building faces another part at close range. Your designer or building control will confirm.
Survey timing in Tiverton depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Tiverton and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.