Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →We provide fire-rated curtain walling in Tiverton and across Devon, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.
In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
Coverage around Tiverton includes the EX16 districts and nearby Exeter, Taunton, Exmouth. Plymouth, around 75 km from Tiverton, is the largest town in the same coverage area.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Tiverton identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Tiverton budgets are not open-ended.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover industrial units, hotels and other buildings in Tiverton.
Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.
Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.
Building work in Tiverton follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We survey and install in Tiverton and across Devon, including the EX16 district and nearby Exeter.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Tiverton confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.