Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →Steel fire-rated screens in Hayes is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
We supply and install tested steel screen systems in black, RAL colours and industrial finishes, including the gridded warehouse look, with integrated single and double doors. Each screen is drawn up within its system evidence so the appearance does not come at the cost of the rating.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Hayes building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Hayes budgets are not open-ended.
Paint and powder coat are normally covered by the evidence, but intumescent strips and seals must not be painted over. We protect them during finishing.
Steel screens with insulating glass are heavy. Fixings are taken from the system details and the substrate is checked to carry the load.
Decorative steel-look aluminium or slim steel partitions sold for offices are not automatically fire-rated. We only fit systems with test or assessment evidence for the classification you need.
Our Greater London coverage takes in Hayes (UB3, UB11, UB4, UB18, UB7, UB1) and the neighbouring towns of Southall, Heston, Greenford. Hayes sits within our Greater London coverage, alongside Southall.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover student accommodation, schools and colleges and other buildings in Hayes.
Some steel systems with that look are tested for fire, many decorative ones are not. Ask for the classification and test evidence; we only quote tested systems for fire-rated positions.
Often slightly, especially at higher ratings, but steel can be the more economical route when panes are large or the rating is EI 60 and above.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Hayes and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.