Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →Our steel fire-rated screens service covers Greenford and neighbouring areas such as Northolt and Southall, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Steel fire-rated screens use steel frame sections to hold fire-resistant glass, and they are the usual choice when a project needs slim sightlines with a high rating, large panes or heavy insulating glass. Steel keeps its strength well in fire and can carry the weight of thick EI glass over long spans.
Steel screens with insulating glass are heavy. Fixings are taken from the system details and the substrate is checked to carry the load.
Paint and powder coat are normally covered by the evidence, but intumescent strips and seals must not be painted over. We protect them during finishing.
Steel profiles stay slim at higher ratings and carry heavy glass without bulky frames, which suits stair cores, lobbies and offices where light matters.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Our Greater London coverage takes in Greenford (UB6, W7, UB5, UB1, UB4, W13) and the neighbouring towns of Northolt, Southall, Brent. We cover Greenford as part of our Greater London coverage.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Greenford budgets are not open-ended.
If an existing frame in a Greenford building has no traceable evidence, we say so and price the options rather than guess.
We can survey and quote for schools and colleges, hotels and other building types in Greenford.
Some steel systems with that look are tested for fire, many decorative ones are not. Ask for the classification and test evidence; we only quote tested systems for fire-rated positions.
Yes. Single, double and in some systems sliding doors can be built into the screen, provided the combination is covered by the evidence.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Greenford to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.