Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →When a fire strategy, inspection report or building control comment in Blackheath calls for glazing tested to resist fire, our steel fire-rated screens service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
We supply and install tested steel screen systems in black, RAL colours and industrial finishes, including the gridded warehouse look, with integrated single and double doors. Each screen is drawn up within its system evidence so the appearance does not come at the cost of the rating.
Coverage around Blackheath includes the SE3, SE13, SE10, SE12, SE8, SE7 districts and nearby Greenwich, Catford, Eltham. Blackheath sits within our Greater London coverage, alongside Greenwich.
Steel profiles stay slim at higher ratings and carry heavy glass without bulky frames, which suits stair cores, lobbies and offices where light matters.
Decorative steel-look aluminium or slim steel partitions sold for offices are not automatically fire-rated. We only fit systems with test or assessment evidence for the classification you need.
Paint and powder coat are normally covered by the evidence, but intumescent strips and seals must not be painted over. We protect them during finishing.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Blackheath budgets are not open-ended.
We can phase work in Blackheath around residents, staff or pupils, with out-of-hours options.
We can survey and quote for healthcare buildings, student accommodation and other building types in Blackheath.
Often slightly, especially at higher ratings, but steel can be the more economical route when panes are large or the rating is EI 60 and above.
Yes. Single, double and in some systems sliding doors can be built into the screen, provided the combination is covered by the evidence.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Blackheath follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Blackheath confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.