Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
South Glamorgan · CF10

Fire-Rated Glazed Screens in Cardiff

When a fire strategy, inspection report or building control comment in Cardiff calls for glazing tested to resist fire, our fire-rated glazed screens service covers survey, supply and installation.

E 30 – EI 120CF10Wales

Quote for Cardiff

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated glazed screens in Cardiff

A fire-rated glazed screen is an internal wall made largely of glass that forms part of a fire-resisting construction, such as a corridor wall, a stair enclosure or a compartment wall. It lets daylight and sightlines through while holding back fire for the period the fire strategy requires.

  • Integrity or insulating glass to the required classification
  • Handover evidence pack
  • Steel, aluminium, timber or frameless frame systems
  • Fire-stopping at head, jambs and sill to the system details

Areas we cover around Cardiff

We cover Cardiff and the surrounding postcode districts, including CF10, CF11, CF24, CF23, CF14. Nearby towns we also serve include Penarth, Caerphilly, Barry. Cardiff is the main town we cover in South Glamorgan.

What to check before ordering fire-rated glazed screens in Cardiff

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Wales regulations that shape the job

Wales Which rules apply?

Building regulations are devolved in Wales, so fire safety design follows the Welsh Ministers' version of Approved Document B rather than the English one, alongside impact safety guidance for glazing.

The Regulatory Reform (Fire Safety) Order 2005 applies in Wales, so the responsible person must maintain fire-resisting glazing as part of the premises' fire safety measures. The Fire Safety Act 2021 confirmed this extends to the structure, external walls and flat entrance doors of multi-occupied residential buildings.

Wales is introducing its own building safety regime for occupied residential buildings, so check current Welsh requirements before planning major works to blocks of flats.

What you can expect in Cardiff

Rated systems, not just rated glass

Every quote in Cardiff identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Honest about unknowns

If an existing frame in a Cardiff building has no traceable evidence, we say so and price the options rather than guess.

Wales rules applied

Designs follow the building and fire safety rules that apply in Wales, not a one-size-fits-all approach.

Building types we cover in Cardiff

Fire-rated glazed screens applies to many building types in Cardiff, including healthcare buildings and blocks of flats.

Questions about fire-rated glazed screens in Cardiff

How large can a fire-rated glazed screen be?

It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.

Can a fire-rated screen be fully glazed?

Yes. Many screens are glazed from floor to ceiling, subject to the classification needed on that route and any impact safety requirements at low level.

How quickly can you survey in Cardiff?

Survey timing in Cardiff depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Do you work on occupied buildings in Cardiff?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Related

Related services in Cardiff

Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Survey

We visit Cardiff to measure, record existing marks and check the frames and substrate.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote