Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · TW9

Fire-Rated Glazed Screens in Richmond, Greater London

If a building in Richmond needs fire-rated glazed screens, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 120TW9England

Quote for Richmond

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated glazed screens in Richmond

A fire-rated glazed screen is an internal wall made largely of glass that forms part of a fire-resisting construction, such as a corridor wall, a stair enclosure or a compartment wall. It lets daylight and sightlines through while holding back fire for the period the fire strategy requires.

  • Handover evidence pack
  • Integrity or insulating glass to the required classification
  • Steel, aluminium, timber or frameless frame systems
  • Survey and setting-out against the fire strategy drawings

What you can expect in Richmond

Rated systems, not just rated glass

Every quote in Richmond identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Honest about unknowns

If an existing frame in a Richmond building has no traceable evidence, we say so and price the options rather than guess.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

What to check before ordering fire-rated glazed screens in Richmond

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

Richmond coverage and nearby towns

Whether the building is in central Richmond or the wider TW9, TW10, TW1, TW2, TW8, SW14 districts, we can survey and quote. We also cover Isleworth, Hounslow, Barnes. Richmond is one of the Greater London districts we cover.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

Richmond building types

Fire-rated glazed screens applies to many building types in Richmond, including healthcare buildings and hotels.

Fire-Rated Glazed Screens: Richmond questions

How large can a fire-rated glazed screen be?

It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.

Can a fire-rated screen be fully glazed?

Yes. Many screens are glazed from floor to ceiling, subject to the classification needed on that route and any impact safety requirements at low level.

Do you work on occupied buildings in Richmond?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Which rules apply to fire-rated glazing in Richmond?

Building work in Richmond follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Richmond

Process

What happens next

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Survey

We visit Richmond to measure, record existing marks and check the frames and substrate.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote