Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · W11

Notting Hill fire-rated glazed screens

For Notting Hill buildings, we supply, replace and check fire-rated glazed screens wherever the fire strategy depends on it, working to the tested system rather than the glass alone.

E 30 – EI 120W11England

Quote for Notting Hill

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated glazed screens in Notting Hill

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Handover evidence pack
  • Steel, aluminium, timber or frameless frame systems
  • Fire-stopping at head, jambs and sill to the system details
  • Integrity or insulating glass to the required classification

Where we work around Notting Hill

Whether the building is in central Notting Hill or the wider W11, W2, W8, W12, W10, W14 districts, we can survey and quote. We also cover Shepherds Bush, Willesden, Fulham. Notting Hill sits within our Greater London coverage, alongside Shepherds Bush.

Key checks for Notting Hill projects

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

What every Notting Hill quote includes

Work around occupied buildings

We can phase work in Notting Hill around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Notting Hill identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Notting Hill budgets are not open-ended.

Sectors we cover in Notting Hill

Fire-rated glazed screens applies to many building types in Notting Hill, including healthcare buildings and blocks of flats.

Fire-Rated Glazed Screens: Notting Hill questions

Can you add a screen to an occupied building?

Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.

Do fire-rated screens need maintenance?

They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.

Do you work on occupied buildings in Notting Hill?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Do you carry out fire-rated glazed screens in Notting Hill?

Yes. We survey and install in Notting Hill and across Greater London, including the W11 district and nearby Shepherds Bush.

Related

Related services in Notting Hill

Process

How a Notting Hill job runs

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Survey

We visit Notting Hill to measure, record existing marks and check the frames and substrate.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.