Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →When a fire strategy, inspection report or building control comment in Notting Hill calls for glazing tested to resist fire, our aluminium fire-rated screens service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Aluminium softens at a lower temperature than steel, so fire-rated aluminium systems rely on specific internal inserts, reinforcements and glazing details. We install only the tested system as a whole, in anodised or powder-coated finishes, with doors and side panels where the evidence allows.
We cover Notting Hill and the surrounding postcode districts, including W11, W2, W8, W12, W10, W14. Nearby towns we also serve include Shepherds Bush, Willesden, Fulham. Notting Hill is one of the Greater London districts we cover.
Fire-rated aluminium profiles contain insulating and intumescent inserts that standard profiles do not. Swapping in a standard section to save cost removes the rating.
Hinges, locks and closers fitted to doors within the screen must be compatible with the door's evidence.
Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
If an existing frame in a Notting Hill building has no traceable evidence, we say so and price the options rather than guess.
We can phase work in Notting Hill around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Sector guides below cover offices, healthcare buildings and other buildings in Notting Hill.
Some systems are tested for external use. If the screen forms part of the building envelope we specify an external-rated system and glass.
Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Notting Hill follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Notting Hill and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.