Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
East Sussex · BN3

Fire-Rated Glazed Screens — Hove and BN3

Looking for fire-rated glazed screens in Hove? We survey, supply and install tested fire-rated glazing for healthcare buildings, care homes and other buildings in and around Hove, including the BN3 postcode district.

E 30 – EI 120BN3England

Quote for Hove

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated glazed screens service includes in Hove

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Integrity or insulating glass to the required classification
  • Survey and setting-out against the fire strategy drawings
  • Handover evidence pack
  • Fire-stopping at head, jambs and sill to the system details

Areas we cover around Hove

Coverage around Hove includes the BN3, BN88, BN50, BN41, BN1 districts and nearby Brighton, Portslade, Burgess Hill. Hove lies roughly 2 km from Brighton, within our East Sussex coverage.

What to check before ordering fire-rated glazed screens in Hove

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

Which rules apply to fire-rated glazed screens in Hove?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

How we work in Hove

Honest about unknowns

If an existing frame in a Hove building has no traceable evidence, we say so and price the options rather than guess.

Work around occupied buildings

We can phase work in Hove around residents, staff or pupils, with out-of-hours options.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Hove budgets are not open-ended.

Hove building types

We can survey and quote for healthcare buildings, care homes and other building types in Hove.

FAQs for Hove

How large can a fire-rated glazed screen be?

It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.

How long does installation take?

Small screens are often fitted in a day once manufactured. Larger runs depend on site access and phasing; we agree a programme with you when we quote.

How quickly can you survey in Hove?

Survey timing in Hove depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Which rules apply to fire-rated glazing in Hove?

Building work in Hove follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Hove

Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Site visit

A survey in Hove confirms sizes, access, existing evidence and fixing conditions.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote