Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Cheshire · CH1

Fire-Rated Glazed Screens — Chester and CH1

Our fire-rated glazed screens service covers Chester and neighbouring areas such as Hawarden and Deeside, with every job built around a tested system.

E 30 – EI 120CH1England

Quote for Chester

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens in Chester: what's included

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Fire-stopping at head, jambs and sill to the system details
  • Handover evidence pack
  • Integrated fire doors and glazed doorsets
  • Steel, aluminium, timber or frameless frame systems

Areas we cover around Chester

Whether the building is in central Chester or the wider CH1, CH88, CH70 districts, we can survey and quote. We also cover Hawarden, Deeside, Ellesmere Port. Chester lies roughly 31 km from Warrington, within our Cheshire coverage.

What to check before ordering fire-rated glazed screens in Chester

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

Which rules apply to fire-rated glazed screens in Chester?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

What you can expect in Chester

Work around occupied buildings

We can phase work in Chester around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Chester identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Sectors we cover in Chester

Sector guides below cover industrial units, schools and colleges and other buildings in Chester.

FAQs for Chester

How long does installation take?

Small screens are often fitted in a day once manufactured. Larger runs depend on site access and phasing; we agree a programme with you when we quote.

Do fire-rated screens need maintenance?

They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.

Which rules apply to fire-rated glazing in Chester?

Building work in Chester follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Do you work on occupied buildings in Chester?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Related

Related services in Chester

Process

How a Chester job runs

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Site visit

A survey in Chester confirms sizes, access, existing evidence and fixing conditions.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote