Frameless Fire-Rated Glazing
Butt-jointed fire glass walls with minimal frames.
Learn more →For Eastleigh buildings, we supply, replace and check fire-rated glass partitions wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass partitions are office-style glazed walls that are also tested to resist fire, used where a meeting room, corridor wall or reception wall forms part of a protected route or compartment. They look like standard office partitions but use rated frames, glass and seals throughout.
A fire-rated partition is only as good as the construction above it. If the wall has to run to the slab, the ceiling void needs fire-stopping or a rated head detail.
Rated partitions need fire-stopping inspected before ceilings close. We plan inspection points into the fit-out programme.
Non-rated partitions on the same floor can be matched in profile and finish.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We cover Eastleigh and the surrounding postcode districts, including SO50, SO53, SO18. Nearby towns we also serve include Southampton, Winchester, Totton. Southampton, around 8 km from Eastleigh, is the largest town in the same coverage area.
Every quote in Eastleigh identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Eastleigh budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Fire-rated glass partitions applies to many building types in Eastleigh, including industrial units and schools and colleges.
Only where the fire strategy says the wall is fire-resisting, for example along a protected escape corridor or a compartment line. Many meeting room walls do not need a rating.
Yes. We can supply and install the rated glazing package within a wider fit-out, working to your programme.
Survey timing in Eastleigh depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Eastleigh follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Butt-jointed fire glass walls with minimal frames.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Eastleigh confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.