Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Looking for fire-rated glazed doors in Eastleigh? We survey, supply and install tested fire-rated glazing for hotels, care homes and other buildings in and around Eastleigh, including the SO50 postcode district.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed fire doorsets in timber, steel and aluminium, single and double, as stand-alone doors or within glazed screens. We match the door to the rating and duty of its position, and fit it to the manufacturer's installation instructions.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can phase work in Eastleigh around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Eastleigh budgets are not open-ended.
Residential blocks in England over 11 metres need regular fire door checks under the Fire Safety (England) Regulations 2022; glazed doors are included.
Each door design allows a maximum glazed area and aperture positions. Bigger glass needs a door tested for it.
Doors that subdivide corridors and doors that swing both ways normally need vision panels, and integrity-only glass in doors may be limited by building guidance on escape routes.
We cover Eastleigh and the surrounding postcode districts, including SO50, SO53, SO18. Nearby towns we also serve include Southampton, Winchester, Totton. Southampton, around 8 km from Eastleigh, is the largest town in the same coverage area.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Fire-rated glazed doors applies to many building types in Eastleigh, including hotels and care homes.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
Cutting new apertures into a fire door is only acceptable when done under the door manufacturer's or certification scheme's instructions. Often a new doorset is the safer answer.
Building work in Eastleigh follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Survey timing in Eastleigh depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Eastleigh confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.