Frameless Fire-Rated Glazing
Butt-jointed fire glass walls with minimal frames.
Learn more →We provide fire-rated glass partitions in Chiswick and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass partitions are office-style glazed walls that are also tested to resist fire, used where a meeting room, corridor wall or reception wall forms part of a protected route or compartment. They look like standard office partitions but use rated frames, glass and seals throughout.
Large glass walls need manifestation so people can see them. Applied film must be compatible with the glass and not cover any marks building control may need to see.
A fire-rated partition is only as good as the construction above it. If the wall has to run to the slab, the ceiling void needs fire-stopping or a rated head detail.
Rated partitions need fire-stopping inspected before ceilings close. We plan inspection points into the fit-out programme.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We cover Chiswick and the surrounding postcode districts, including W4, W3, SW13, W6, W14, W12. Nearby towns we also serve include Acton, Barnes, Shepherds Bush. Chiswick is one of the Greater London districts we cover.
We can phase work in Chiswick around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Chiswick identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Sector guides below cover offices, schools and colleges and other buildings in Chiswick.
Only where the fire strategy says the wall is fire-resisting, for example along a protected escape corridor or a compartment line. Many meeting room walls do not need a rating.
Some butt-jointed systems are tested for fire. See our frameless fire-rated glazing service for what is possible.
Yes. We survey and install in Chiswick and across Greater London, including the W4 district and nearby Acton.
Building work in Chiswick follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Butt-jointed fire glass walls with minimal frames.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Chiswick confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.