Our fire-rated glass partitions service covers Cambridge and neighbouring areas such as Newmarket and Ely, with every job built around a tested system.

E 30 – EI 60CB21England

Quote for Cambridge

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glass Partitions in Cambridge: what's included

Office fit-outs often only need fire-rated glazing on certain lines, such as corridors that serve as escape routes. We work from your fire strategy to rate only what needs rating, and match the look across the rest of the floor so the design stays consistent.

  • Single-glazed and double-glazed rated options where tested
  • Perimeter and ceiling-void fire-stopping
  • Coordination with your fit-out contractor
  • Fire-rated partition systems for office fit-outs

Areas we cover around Cambridge

Survey visits can be arranged anywhere in Cambridge, including the CB21, CB2, CB3, CB1, CB4, CB5 districts, and in nearby Newmarket, Ely, Huntingdon. Peterborough, around 48 km from Cambridge, is the largest town in the same coverage area.

What to check before ordering fire-rated glass partitions in Cambridge

Acoustic privacy

Meeting rooms often need acoustic performance too. Some fire partition systems are tested for both; we confirm the combination.

Fit-out sequencing

Rated partitions need fire-stopping inspected before ceilings close. We plan inspection points into the fit-out programme.

Dilapidations and moves

Demountable systems can be reconfigured, but moving a rated partition means rechecking its evidence and fire-stopping in the new position.

Which rules apply to fire-rated glass partitions in Cambridge?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

What you can expect in Cambridge

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Rated systems, not just rated glass

Every quote in Cambridge identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Cambridge budgets are not open-ended.

Cambridge building types

Fire-rated glass partitions applies to many building types in Cambridge, including schools and colleges and public buildings.

Questions about fire-rated glass partitions in Cambridge

Do office glass partitions need to be fire-rated?

Only where the fire strategy says the wall is fire-resisting, for example along a protected escape corridor or a compartment line. Many meeting room walls do not need a rating.

Will a fire-rated partition look different?

Frames may be slightly deeper and glass slightly thicker, but most systems are hard to tell apart from standard partitions.

Do you carry out fire-rated glass partitions in Cambridge?

Yes. We survey and install in Cambridge and across Cambridgeshire, including the CB21 district and nearby Newmarket.

Which rules apply to fire-rated glazing in Cambridge?

Building work in Cambridge follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Cambridge

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

From enquiry to handover in Cambridge

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Measure and check

We measure each opening in Cambridge and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.