Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →We provide fire-rated glass floors in Newton Mearns and across Renfrewshire and Inverclyde, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Obscured or patterned surfaces can be specified within the system for privacy below.
Glass floors are made to order with longer lead times; we plan early with your contractor.
Our Renfrewshire and Inverclyde coverage takes in Newton Mearns (G77, G76, G46, G53) and the neighbouring towns of Paisley, Rutherglen, East Kilbride. Paisley, around 9 km from Newton Mearns, is the largest town in the same coverage area.
Designs follow the building and fire safety rules that apply in Scotland, not a one-size-fits-all approach.
If an existing frame in a Newton Mearns building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Newton Mearns identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Sector guides below cover hotels, industrial units and other buildings in Newton Mearns.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Survey timing in Newton Mearns depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Newton Mearns confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.