Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Our fire-rated glass floors service covers Chelsea and neighbouring areas such as Battersea and Fulham, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glass floor is a walk-on glazed floor panel, set in a tested support frame, that keeps both its load-bearing capacity and its fire resistance for a stated time. Because a floor carries load, its classification also includes R for load-bearing capacity alongside integrity and insulation.
Every quote in Chelsea identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
After survey you get a fixed written quote for the agreed scope, so Chelsea budgets are not open-ended.
Glass floors are made to order with longer lead times; we plan early with your contractor.
Walk-on glass needs an anti-slip finish; it must be one covered by the system.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
Survey visits can be arranged anywhere in Chelsea, including the SW10, SW3, SW7, SW1X, SW5, W1M districts, and in nearby Battersea, Fulham, Pimlico. We cover Chelsea as part of our Greater London coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for blocks of flats, offices and other building types in Chelsea.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Survey timing in Chelsea depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Chelsea and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.