EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →If a building in Battersea needs fire-rated glass floors, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
Whether the building is in central Battersea or the wider SW11, SW3, SW10, SW4, SW8, SW1 districts, we can survey and quote. We also cover Chelsea, Pimlico, Westminster. We cover Battersea as part of our Greater London coverage.
Obscured or patterned surfaces can be specified within the system for privacy below.
Glass floors are made to order with longer lead times; we plan early with your contractor.
Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can phase work in Battersea around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Battersea budgets are not open-ended.
If an existing frame in a Battersea building has no traceable evidence, we say so and price the options rather than guess.
We can survey and quote for offices, retail and leisure units and other building types in Battersea.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Each system sets maximum panel sizes; larger areas are divided by a supporting grid.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Survey timing in Battersea depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Battersea to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.