Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →From the BT51 district outwards, we arrange fire-rated glass floors for buildings across Coleraine, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
After survey you get a fixed written quote for the agreed scope, so Coleraine budgets are not open-ended.
We can phase work in Coleraine around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in Northern Ireland, not a one-size-fits-all approach.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Obscured or patterned surfaces can be specified within the system for privacy below.
Our County Londonderry coverage takes in Coleraine (BT51, BT52) and the neighbouring towns of Ballymena, Derry / Londonderry, Newtownabbey. Coleraine is about 44 km from Derry / Londonderry, the largest town in our County Londonderry coverage.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
Technical Booklet E sets its own provisions for glazing on escape routes, so designs are checked against the Northern Ireland guidance rather than English documents.
We can survey and quote for schools and colleges, public buildings and other building types in Coleraine.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Coleraine and across County Londonderry, including the BT51 district and nearby Ballymena.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Coleraine and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.