Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →When a fire strategy, inspection report or building control comment in Newquay calls for glazing tested to resist fire, our fire-rated glass floors service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Newquay budgets are not open-ended.
If an existing frame in a Newquay building has no traceable evidence, we say so and price the options rather than guess.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
Walk-on glass needs an anti-slip finish; it must be one covered by the system.
Survey visits can be arranged anywhere in Newquay, including the TR7, TR8 districts, and in nearby Truro, St Austell, Redruth. Truro, around 23 km from Newquay, is the largest town in the same coverage area.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for retail and leisure units, industrial units and other building types in Newquay.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
Each system sets maximum panel sizes; larger areas are divided by a supporting grid.
Survey timing in Newquay depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Newquay confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.