Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Cheshire · CW1

Fire-Rated Glass Floors across Crewe

From the CW1 district outwards, we arrange fire-rated glass floors for buildings across Crewe, matching glass, frames and seals to tested evidence rather than guesswork.

REI 30 – 60CW1England

Quote for Crewe

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated glass floors in Crewe

Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.

  • Tested walk-on fire-rated glass floor systems
  • Coordination with the structural engineer
  • Horizontal fire-rated rooflights
  • Handover evidence

What to check before ordering fire-rated glass floors in Crewe

Load and fire together

A glass floor must carry its design load during the fire period. Only systems tested for both should be used.

Slip resistance

Walk-on glass needs an anti-slip finish; it must be one covered by the system.

Programme

Glass floors are made to order with longer lead times; we plan early with your contractor.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Where we work around Crewe

Whether the building is in central Crewe or the wider CW1, CW2, CW5 districts, we can survey and quote. We also cover Winsford, Kidsgrove, Congleton. Crewe lies roughly 34 km from Warrington, within our Cheshire coverage.

How we work in Crewe

Work around occupied buildings

We can phase work in Crewe around residents, staff or pupils, with out-of-hours options.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Honest about unknowns

If an existing frame in a Crewe building has no traceable evidence, we say so and price the options rather than guess.

Crewe building types

Fire-rated glass floors applies to many building types in Crewe, including industrial units and retail and leisure units.

Fire-Rated Glass Floors: Crewe questions

What does REI mean?

R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.

How big can a fire-rated glass floor panel be?

Each system sets maximum panel sizes; larger areas are divided by a supporting grid.

Which rules apply to fire-rated glazing in Crewe?

Building work in Crewe follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Can you price fire-rated glass floors in Crewe from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in Crewe

E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

From enquiry to handover in Crewe

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Site visit

A survey in Crewe confirms sizes, access, existing evidence and fixing conditions.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote