Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →For Crewe buildings, we supply, replace and check insulated fire glass wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
Some EI products are internal only. External use needs a product and edge seal approved for UV and weather.
Survey visits can be arranged anywhere in Crewe, including the CW1, CW2, CW5 districts, and in nearby Winsford, Kidsgrove, Congleton. Crewe lies roughly 34 km from Warrington, within our Cheshire coverage.
We can phase work in Crewe around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Crewe building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Crewe identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for healthcare buildings, blocks of flats and other building types in Crewe.
It is a multi-layer product with specialist interlayers, and the frame and installation must suit its weight.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Crewe follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Crewe to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.