Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →For Kenilworth buildings, we supply, replace and check frameless fire-rated glazing wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire-rated glazing is a glass wall where panes meet edge to edge with a tested sealant joint instead of vertical frames, held in discreet head and base channels. It gives an almost uninterrupted view while still being tested to resist fire.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Channels at the head have to allow for slab movement without loading the glass.
Frameless glass is exposed during the build. We plan protection until other trades finish.
Survey visits can be arranged anywhere in Kenilworth, including the CV8, CV4 districts, and in nearby Warwick, Coventry, Royal Leamington Spa. Kenilworth lies roughly 21 km from Nuneaton, within our Warwickshire coverage.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Kenilworth building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for schools and colleges, blocks of flats and other building types in Kenilworth.
Yes, typically. It also needs more careful site protection.
Usually through a slim framed door set into the run, chosen so the combination is covered by evidence.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Survey timing in Kenilworth depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Kenilworth to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.