Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →If a building in Woking needs frameless fire-rated glazing, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
We can phase work in Woking around residents, staff or pupils, with out-of-hours options.
Every quote in Woking identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Frameless fire glazing is at the top of the price range because of the glass and precision required.
Channels at the head have to allow for slab movement without loading the glass.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
Survey visits can be arranged anywhere in Woking, including the GU22, GU21 districts, and in nearby Guildford, Egham, Walton-on-Thames. Woking is the main town we cover in Surrey.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover public buildings, blocks of flats and other buildings in Woking.
Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.
Yes, typically. It also needs more careful site protection.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Woking and across Surrey, including the GU22 district and nearby Guildford.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Woking confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.