Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →From the GU15 district outwards, we arrange frameless fire-rated glazing for buildings across Camberley, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
Frameless glass is exposed during the build. We plan protection until other trades finish.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Our Surrey coverage takes in Camberley (GU15, GU17, GU47, GU16, GU19) and the neighbouring towns of Sandhurst, Farnborough, Crowthorne. Camberley is about 13 km from Woking, the largest town in our Surrey coverage.
We can phase work in Camberley around residents, staff or pupils, with out-of-hours options.
Every quote in Camberley identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover retail and leisure units, public buildings and other buildings in Camberley.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Yes, typically. It also needs more careful site protection.
Yes. We survey and install in Camberley and across Surrey, including the GU15 district and nearby Sandhurst.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Camberley and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.