Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · CR4

Frameless Fire-Rated Glazing in Mitcham, Greater London

If a building in Mitcham needs frameless fire-rated glazing, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 60CR4England

Quote for Mitcham

Tell us what you need. We reply with next steps and a guide price.

What our frameless fire-rated glazing service includes in Mitcham

Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.

  • Frameless-look fire doors where tested
  • Handover evidence
  • Manifestation design
  • Tested butt-jointed insulating or integrity glass systems

Before you order frameless fire-rated glazing: what matters

Deflection

Channels at the head have to allow for slab movement without loading the glass.

The joint is part of the test

The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.

Cost

Frameless fire glazing is at the top of the price range because of the glass and precision required.

Mitcham coverage and nearby towns

Survey visits can be arranged anywhere in Mitcham, including the CR4, SM4, SW19, SW17, SW16, SM5 districts, and in nearby Morden, Wimbledon, Streatham. We cover Mitcham as part of our Greater London coverage.

What you can expect in Mitcham

Honest about unknowns

If an existing frame in a Mitcham building has no traceable evidence, we say so and price the options rather than guess.

Rated systems, not just rated glass

Every quote in Mitcham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Mitcham budgets are not open-ended.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Building types we cover in Mitcham

Sector guides below cover retail and leisure units, schools and colleges and other buildings in Mitcham.

Frameless Fire-Rated Glazing: Mitcham questions

Is frameless more expensive than framed?

Yes, typically. It also needs more careful site protection.

How tall can frameless fire glass go?

Each system states a maximum height. We check your floor-to-ceiling height against it during design.

Which rules apply to fire-rated glazing in Mitcham?

Building work in Mitcham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

How quickly can you survey in Mitcham?

Survey timing in Mitcham depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Mitcham

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Survey

We visit Mitcham to measure, record existing marks and check the frames and substrate.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote