Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →Frameless fire-rated glazing in Wallington is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire-rated glazing is a glass wall where panes meet edge to edge with a tested sealant joint instead of vertical frames, held in discreet head and base channels. It gives an almost uninterrupted view while still being tested to resist fire.
Coverage around Wallington includes the SM6, SM5, CR4, SM2, SM1, CR7 districts and nearby Carshalton, Sutton, South Croydon. Wallington is one of the Greater London districts we cover.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
Frameless fire glazing is at the top of the price range because of the glass and precision required.
Channels at the head have to allow for slab movement without loading the glass.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can phase work in Wallington around residents, staff or pupils, with out-of-hours options.
Every quote in Wallington identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can survey and quote for offices, healthcare buildings and other building types in Wallington.
Yes, typically. It also needs more careful site protection.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Survey timing in Wallington depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Wallington confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.