Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →We provide fire-rated fanlights and side panels in Washington and across Tyne and Wear, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Fanlights, side panels and borrowed lights are the glazed panels above and beside doors, or set into internal walls to share daylight between rooms. Where the wall or door around them is fire-resisting, the glazing must be fire-rated too, or it becomes the weak point.
Our Tyne and Wear coverage takes in Washington (NE37, NE38) and the neighbouring towns of Chester-le-Street, Felling, Houghton-le-Spring. Washington is about 10 km from Newcastle upon Tyne, the largest town in our Tyne and Wear coverage.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Washington budgets are not open-ended.
We can phase work in Washington around residents, staff or pupils, with out-of-hours options.
Sector guides below cover retail and leisure units, healthcare buildings and other buildings in Washington.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Building work in Washington follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We survey and install in Washington and across Tyne and Wear, including the NE37 district and nearby Chester-le-Street.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Washington and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.