Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →From the S1 district outwards, we arrange fire-rated fanlights and side panels for buildings across Sheffield, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Whether the building is in central Sheffield or the wider S1, S2, S3, S4, S7, S11 districts, we can survey and quote. We also cover Rotherham, Dronfield, Chapeltown. Sheffield is the main town we cover in South Yorkshire.
After survey you get a fixed written quote for the agreed scope, so Sheffield budgets are not open-ended.
Every quote in Sheffield identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can survey and quote for offices, healthcare buildings and other building types in Sheffield.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Sheffield confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.