Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →From the ME7 district outwards, we arrange fire-rated fanlights and side panels for buildings across Gillingham, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Our Kent coverage takes in Gillingham (ME7, ME4, ME5, ME8) and the neighbouring towns of Chatham, Rochester, Strood. Gillingham lies roughly 14 km from Maidstone, within our Kent coverage.
We can phase work in Gillingham around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Gillingham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Fire-rated fanlights and side panels applies to many building types in Gillingham, including blocks of flats and offices.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Gillingham confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.