Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →For South Croydon buildings, we supply, replace and check fire-rated fanlights and side panels wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Fanlights, side panels and borrowed lights are the glazed panels above and beside doors, or set into internal walls to share daylight between rooms. Where the wall or door around them is fire-resisting, the glazing must be fire-rated too, or it becomes the weak point.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
If the existing frame can be shown to be suitable, new glass and seals may be enough; otherwise a complete rated frame is the reliable answer.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Whether the building is in central South Croydon or the wider CR0, CR7, CR9, CR2, CR8, SM6 districts, we can survey and quote. We also cover Croydon, Purley, Wallington. South Croydon sits within our Greater London coverage, alongside Croydon.
Every quote in South Croydon identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so South Croydon budgets are not open-ended.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover healthcare buildings, offices and other buildings in South Croydon.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in South Croydon and across Greater London, including the CR0 district and nearby Croydon.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in South Croydon confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.