Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →If a building in Reading needs fire-rated fanlights and side panels, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
Our Berkshire coverage takes in Reading (RG1, RG4, RG30, RG6, RG2) and the neighbouring towns of Earley, Wokingham, Crowthorne. Reading is the largest town in our Berkshire coverage.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Every quote in Reading identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Reading building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Sector guides below cover public buildings, offices and other buildings in Reading.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
Yes. We survey and install in Reading and across Berkshire, including the RG1 district and nearby Earley.
Building work in Reading follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Reading to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.