Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →Our fire door vision panels service covers Reading and neighbouring areas such as Earley and Wokingham, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
A fire door vision panel is the glazed opening in a fire door that lets people see through it. It is part of the door's fire rating: the glass, beads, glazing seals and the size and position of the opening all have to match the door's test or certification evidence.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Reading identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Reading building has no traceable evidence, we say so and price the options rather than guess.
Old wired glass often provides integrity but not impact safety. Upgrading to modern fire glass with an impact classification removes a common risk in schools and corridors.
We photograph each panel before and after and note the glass marks, so your fire door records stay complete.
Ordinary float or toughened glass in a fire door vision panel is a serious defect. We replace it with fire-resistant glass compatible with the door.
We cover Reading and the surrounding postcode districts, including RG1, RG4, RG30, RG6, RG2. Nearby towns we also serve include Earley, Wokingham, Crowthorne. Reading is the main town we cover in Berkshire.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover blocks of flats, healthcare buildings and other buildings in Reading.
It may provide integrity, but it often fails impact safety requirements. Replacement with modern fire glass is usually recommended.
Not always. Building guidance expects vision panels in doors that subdivide corridors and in double-swing doors, and accessibility guidance favours them in many circulation doors.
Survey timing in Reading depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Reading and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.