Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
England · 1 postcode district

Fanlights, Side Panels & Borrowed Lights in Rutland

Fire-rated fanlights and side panels across Rutland covers 1 postcode district in the LE postcode areas. Every job is built around a tested system.

30 / 60 minEnglandLE

Quote for Rutland

Tell us what you need. We reply with next steps and a guide price.

Communal hallway with a timber door, glazed fanlight above and glazed side panel

Fanlights, Side Panels & Borrowed Lights: an overview for Rutland

These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.

  • Fire-rated fanlights above fire doors
  • Glazed side panels beside fire doors
  • Complete replacement frames where needed

Places we cover in Rutland

We cover fire-rated fanlights and side panels in Oakham and across Rutland, including Uppingham.

What to check before ordering in Rutland

Borrowed lights

Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.

Often overlooked

Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.

Impact safety

Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.

Which rules apply in England?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Fanlights, Side Panels & Borrowed Lights in Rutland: questions

Does the glass above a fire door need to be fire-rated?

If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.

Do side panels need safety glass too?

Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.

What is a borrowed light?

An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.

Do you cover all of Rutland?

Yes. We take enquiries from across Rutland, including Oakham and Uppingham, and arrange surveys to suit your programme.

Related

Related services in Rutland

Process

What happens next

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Measure and check

We measure each opening in Rutland and check what the existing frames can accept.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote