Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →Our fire-rated curtain walling service covers Leatherhead and neighbouring areas such as Epsom and Ewell, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.
Coverage around Leatherhead includes the KT22, KT21, KT23, KT18 districts and nearby Epsom, Ewell, Esher. Leatherhead lies roughly 16 km from Woking, within our Surrey coverage.
External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Leatherhead identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Leatherhead budgets are not open-ended.
Fire-rated curtain walling applies to many building types in Leatherhead, including schools and colleges and blocks of flats.
Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.
Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Leatherhead follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Leatherhead and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.