Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Surrey · KT10

Fire-Rated Curtain Walling across Esher

Our fire-rated curtain walling service covers Esher and neighbouring areas such as Walton-on-Thames and Hampton, with every job built around a tested system.

E 30 – EI 60KT10England

Quote for Esher

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated curtain walling in Esher

We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.

  • Slab-edge fire-stopping and cavity barriers to the design
  • External-grade fire glass
  • Tested fire-rated curtain wall systems
  • Spandrel and opaque panel coordination

Where we work around Esher

Coverage around Esher includes the KT10, KT7, KT12, KT8, KT9, TW12 districts and nearby Walton-on-Thames, Hampton, Sunbury-on-Thames. Woking, around 14 km from Esher, is the largest town in the same coverage area.

Before you order fire-rated curtain walling: what matters

Slab edges

The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

What you can expect in Esher

Work around occupied buildings

We can phase work in Esher around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Esher identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Sectors we cover in Esher

Fire-rated curtain walling applies to many building types in Esher, including hotels and schools and colleges.

Fire-Rated Curtain Walling: Esher questions

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Do you carry out fire-rated curtain walling in Esher?

Yes. We survey and install in Esher and across Surrey, including the KT10 district and nearby Walton-on-Thames.

How quickly can you survey in Esher?

Survey timing in Esher depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Esher

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Survey

We visit Esher to measure, record existing marks and check the frames and substrate.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote