Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →From the KT10 district outwards, we arrange integrity fire glass for buildings across Esher, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Integrity fire glass, classified E, stops flames and hot gases passing for the rated time but does not limit the heat coming through. EW glass adds a cap on the heat radiated through the glass. Both are thinner, lighter and cheaper than fully insulated glass.
Coverage around Esher includes the KT10, KT7, KT12, KT8, KT9, TW12 districts and nearby Walton-on-Thames, Hampton, Sunbury-on-Thames. Esher lies roughly 14 km from Woking, within our Surrey coverage.
Integrity glass costs a fraction of insulated glass and fits slimmer frames, which is why specifying it correctly matters.
Integrity-only glass may be acceptable in some fire-resisting partitions, screens and doors, often at high level, within the limits national guidance sets. Compartment walls normally need insulating (EI) glazing.
EW glass limits radiation to 15 kW/m² measured one metre from the glass, reducing the risk of igniting materials or harming people nearby.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
If an existing frame in a Esher building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Esher identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Esher around residents, staff or pupils, with out-of-hours options.
We can survey and quote for industrial units, offices and other building types in Esher.
Glass that stops flames and hot gases for the rated time but lets heat through. It is classified E.
In limited amounts and positions. Building guidance sets the rules; insulating glass is used where those limits are exceeded.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Esher follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Esher to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.