Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →When a fire strategy, inspection report or building control comment in Tonypandy calls for glazing tested to resist fire, our fire-rated curtain walling service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
Building regulations are devolved in Wales, so fire safety design follows the Welsh Ministers' version of Approved Document B rather than the English one, alongside impact safety guidance for glazing.
The Regulatory Reform (Fire Safety) Order 2005 applies in Wales, so the responsible person must maintain fire-resisting glazing as part of the premises' fire safety measures. The Fire Safety Act 2021 confirmed this extends to the structure, external walls and flat entrance doors of multi-occupied residential buildings.
Wales is introducing its own building safety regime for occupied residential buildings, so check current Welsh requirements before planning major works to blocks of flats.
Survey visits can be arranged anywhere in Tonypandy, including the CF40, CF39, CF41 districts, and in nearby Rhondda, Pontypridd, Aberdare. Rhondda, around 4 km from Tonypandy, is the largest town in the same coverage area.
Designs follow the building and fire safety rules that apply in Wales, not a one-size-fits-all approach.
We can phase work in Tonypandy around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Tonypandy budgets are not open-ended.
Sector guides below cover healthcare buildings, schools and colleges and other buildings in Tonypandy.
Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Survey timing in Tonypandy depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Tonypandy to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.