Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Scotland · 24 postcode districts

Fire-Rated Curtain Walling in Lanarkshire

We take fire-rated curtain walling enquiries from across Lanarkshire, with surveys arranged in East Kilbride, Hamilton, Cumbernauld, Coatbridge, Airdrie and the surrounding towns.

E 30 – EI 60ScotlandGML

Quote for Lanarkshire

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated curtain walling service includes in Lanarkshire

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • Tested fire-rated curtain wall systems
  • Slab-edge fire-stopping and cavity barriers to the design
  • Handover evidence for the building record

What to check before ordering in Lanarkshire

External-grade glass

External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Thermal and acoustic

Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.

Towns we cover in Lanarkshire

Lanarkshire coverage includes East Kilbride, Hamilton, Cumbernauld, Coatbridge, Airdrie and the G, ML postcode areas (24 postcode districts).

Regulations for Lanarkshire projects

Scotland Which rules apply?

In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.

For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.

Fire-Rated Curtain Walling in Lanarkshire: questions

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

Do you work on high-rise buildings?

We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.

Can you survey anywhere in Lanarkshire?

Yes. We can arrange surveys anywhere in Lanarkshire, including East Kilbride and Hamilton, Cumbernauld, Coatbridge, Airdrie.

Related

Related services in Lanarkshire

Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Survey

We visit Lanarkshire to measure, record existing marks and check the frames and substrate.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote