Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · W12

Fire-Rated Curtain Walling — Shepherds Bush and W12

From the W12 district outwards, we arrange fire-rated curtain walling for buildings across Shepherds Bush, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 60W12England

Quote for Shepherds Bush

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Curtain Walling in Shepherds Bush: what's included

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • Tested fire-rated curtain wall systems
  • External-grade fire glass
  • Fire-rated zones within mixed facades
  • Handover evidence for the building record

Where we work around Shepherds Bush

We cover Shepherds Bush and the surrounding postcode districts, including W12, W14, W11, W6, W8, W10. Nearby towns we also serve include Notting Hill, Chiswick, Fulham. Shepherds Bush is one of the Greater London districts we cover.

What to check before ordering fire-rated curtain walling in Shepherds Bush

Slab edges

The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

What every Shepherds Bush quote includes

Honest about unknowns

If an existing frame in a Shepherds Bush building has no traceable evidence, we say so and price the options rather than guess.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Shepherds Bush budgets are not open-ended.

Rated systems, not just rated glass

Every quote in Shepherds Bush identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Building types we cover in Shepherds Bush

Fire-rated curtain walling applies to many building types in Shepherds Bush, including public buildings and offices.

Questions about fire-rated curtain walling in Shepherds Bush

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

Do you carry out fire-rated curtain walling in Shepherds Bush?

Yes. We survey and install in Shepherds Bush and across Greater London, including the W12 district and nearby Notting Hill.

How quickly can you survey in Shepherds Bush?

Survey timing in Shepherds Bush depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Shepherds Bush

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Measure and check

We measure each opening in Shepherds Bush and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote