Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · SM4

Fire-Rated Curtain Walling across Morden

We provide fire-rated curtain walling in Morden and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.

E 30 – EI 60SM4England

Quote for Morden

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated curtain walling service includes in Morden

We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.

  • Slab-edge fire-stopping and cavity barriers to the design
  • Spandrel and opaque panel coordination
  • Fire-rated zones within mixed facades
  • External-grade fire glass

Before you order fire-rated curtain walling: what matters

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

Thermal and acoustic

Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Areas we cover around Morden

Survey visits can be arranged anywhere in Morden, including the SM4, SW20, CR4, SW19, KT4, SM5 districts, and in nearby Mitcham, Wimbledon, Carshalton. We cover Morden as part of our Greater London coverage.

What you can expect in Morden

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Morden budgets are not open-ended.

Honest about unknowns

If an existing frame in a Morden building has no traceable evidence, we say so and price the options rather than guess.

Which rules apply to fire-rated curtain walling in Morden?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Sectors we cover in Morden

Sector guides below cover hotels, schools and colleges and other buildings in Morden.

Fire-Rated Curtain Walling: Morden questions

Do you work on high-rise buildings?

We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Which rules apply to fire-rated glazing in Morden?

Building work in Morden follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Do you carry out fire-rated curtain walling in Morden?

Yes. We survey and install in Morden and across Greater London, including the SM4 district and nearby Mitcham.

Related

Related services in Morden

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

How a Morden job runs

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Site visit

A survey in Morden confirms sizes, access, existing evidence and fixing conditions.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote